Others

HK-0093 Solid Particulate Pollutant Tester for Fuel Jet

HK-0093 Solid particulate pollutant tester for fuel jet conforms to the ASTM D2276 Standard Test Method for Particulate Contaminant in Aviation Fuel by Line Sampling.

 

The apparatus provides a gravimetric measurement of the particulate matter present in a sample of aviation turbine fuel by line sampling.

 

The objective is to minimize these contaminants to avoid filter plugging and other operational problem .It is used to test particulate contaminant in aviation turbine fuel using a field monitor.

Technical parameters

1.Rated voltage:AC220V±10%  50Hz

2.Power:250W

3.Pressure display:0~ 0.1 MPa

4.Glass sand core filter:5L

5.Filter film sheet:0.8um≤0.1g

6.Limit negative pressure value:≥0.09 MPa

7.Adjustment range:0.02MPa ~ 0.09MPa

8.Exhaust rate:> 20L/min

9.Solvent bottle:500ml

10.Ambient requirementsTemperature:10~40°C;Humidity≤85%

HK-0109 Apparatus for the Determination Of Water Washout Characteristics Of Lubricating Grease

HK-0109 apparatus for the determination of Water Washout Characteristics of Lubricating Greases conforms to the ASTM D1264 standard.

 

This apparatus covers the evaluation of the resistance of a lubricating grease to washout by water from a bearing, when tested at 38 and 79°C (100 and 175°F) under the prescribed laboratory conditions. It is not to be considered the equivalent of service evaluation tests. Precision and bias was determined using grease ranging from NLGI 3 to 0 grades in the research report

Technical parameters

1.Rated voltage: AC 220V±10% 50Hz or 110V±10% 60Hz

2.Sink heating power: 500W

3.Sink temperature range: Room temperature ~ 100℃,continuously adjustable

4.Control temperature accuracy: ± 2 ℃

5.Total power: 600 W

6.Spray water: 5 ± 0.5ml/s.

7.Bearing speed: 600 ± 30r/min

8.Ambient requirements: Temperature: 10~40℃;Humidity≤85%

HK-507A Insulating Oil Dielectric Breakdown Tester

Oils that combine a high flashpoint with high dielectric strength have long been used as an insulating medium in transformers, switchgear and other electrical apparatus. To ensure that the dielectric strength of the oil does not deteriorate however, proper maintenance is essential, and the basis of proper maintenance is testing.

 

For many electric equipments used in power system and enterprises, inner insulation is mostly oil-insulated. Oil dielectric strength test is one of the essential routine tests.  

 

Our HK-507A oil dielectric breakdown tester is the ideal testing device for oil dielectric strength. The test sets are fully automatic. Our products have been used by many power enterprises all over the world.

Technical parameters

1.Voltage: AC220V±10%

2.Frequency : 50 Hz ± 1Hz

3.Power : < 200W

4.Output :0~60kV\; 0~80kV(alternative)

5.Voltage booster capacity: 1.5kVA

6.Voltage rise rate: 2.0 ; 3.0; (adjustable)

7.Voltage total harmonic distortion: <3%    

8.Dimension : 470 X 390 X 4209.Weight: 40kg

HK-0308 Air Release Value Apparatus

HK-0308 Air release value apparatus conforms to the ASTM D3427 standard Test Method for Air Release Properties of Petroleum Oils.

 

It is used to test the ability of turbine, hydraulic, and gear oils to separate entrained air. This apparatus measures the time for the entrained air content to fall to the relatively low value of 0.2 % volume under a standardized set of test conditions and hence permits the comparison of the ability of oils to separate entrained air under conditions where a separation time is available. The significance of this test method has not been fully established.

 

However, entrained air can cause sponginess and lack of sensitivity of the control of turbine and hydraulic systems. This test may not be suitable for ranking oils in applications where residence times are short and gas contents are high

Technical parameters

1.Rated voltage: AC 220V±10% 50Hz

2.Power: 600W

3.Temperature: Digital display temperature controller

4.Temperature range: Room temperature ~ 100°C

5.Control precision: ±0.1°C

6.Temperature sensor: Pt100 (Platinum resistor)

7.Cycle mode: Pump cycle

8.Ambient requirements: Temperature 10~40°C; Humidity≤85%